Error 250:  MPI® DESS® post data corrupted

Navigation:  B.U.D.S. > Troubleshooting >

Error 250:  MPI® DESS® post data corrupted

Previous pageReturn to chapter overviewNext page

Description

The data that the MPI read from its DESS post was corrupted.

Possible causes

1.The key contacts are rusted or dirty.
2.The key is defective.
3.The MPI is defective.

Suggested actions

1.Maintain a light pressure with your hand on the key while reading it.
2.Try to read the key again.
3.Insert another key on the MPI DESS post.
4.Replace the MPI.