B.U.D.S. > User Interface > Document > Faults > More Details Page
Faults conditions
The following engine parameters are provided for all faults that are stored in the ECM and show the conditions that prevailed when the fault occured:
 | Speed (RPM): |
|
|
 | TPS (%): |
|
| The throttle opening in percent. |
|
 | Intake (PSI): |
|
|
 | Intake (°F): |
|
| The intake air temperature. |
|
 | Engine (°F): |
|
|
 | Exhaust (°F): |
|
|
 | Battery (V): |
|
|
 | Vehicle Speed (MPH): |
|
| The vehicle speed (Set to zero when not available in the ECM). |
|
 | Engine Status: |
|
| The engine status when the fault occured. Possible status are: |
|
|
|
The engine was running with normal part load operating conditions.
|
|
|
The engine idle contact was closed.
|
|
|
The engine was running full load.
|
|
|
The engine idle contact was closed and fuel cut off was active.
|
 | Driving Cycles: |
|
| The number of times the engine had started when the first occurrence of the fault appeared. |
|
To clear fault conditions
To clear the conditions associated to a fault you must clear that fault. To do so, follow these steps:
| 1. | Select a fault that has a double star (**) preceding the fault code in the Summary table. |
| 2. | Click on the Clear Fault button. |
| 3. | Click on the message box Yes button. |
| 4. | Wait until B.U.D.S. clears the fault and the fault conditions into the module. |
To activate a faulty output
If the fault that is currently displayed in the More Details page concerns a module output, then you can activate it directly by pressing the Activate Component button. If the fault does not concern a module output or if the engine is running, then the button is disabled.