Error 510:  Diagnostic function was running but suddenly failed

Navigation:  B.U.D.S. > Troubleshooting >

Error 510:  Diagnostic function was running but suddenly failed

Previous pageReturn to chapter overviewNext page

Description

The MPEM indicates that the diagnostic function that you initiated was running, but suddenly failed during the execution.

Possible causes

1.The MPEM input sensor is out-of-range.
2.The MPEM output driver circuit failed.
3.The target component is defective.
4.The software inside the MPEM failed.

Suggested actions

1.Make sure that the input value is within a valid range.
_bm0If you are resetting the closed TPS, then make sure that the idle speed screw is in contact with the throttle plate stopper and try the command again.
2.Make sure that the target component is not defective.
3.Try the command again.