947-DI Faults Page
Description
The Summary table displays 7 parameters for each fault. Parameters are continuously and automatically updated at a rate of about two times per second. The example below shows the parameters of a battery fault:
To clear a particular fault
| 1. | Select the fault in the Summary table. |
| 2. | Click on the Clear Fault button. |
| 3. | Click on the message box Yes button. |
| 4. | Wait until B.U.D.S. clears the fault into the MPEM. |
To clear all occurred faults
| 1. | Click on the Clear Occurred Faults button. |
| 2. | Click on the message box Yes button. |
| 3. | Wait until B.U.D.S. clears all occurred faults into the MPEM. |
Notes
Clearing a fault resets the Count and First time stamp to zero, increments the Clear counter by one and sets the Last time stamp to the current engine hours. The status of the fault, which is controlled by the MPEM, remains the same.
If you clear the fault that has a double star (**) preceding the fault code, then the conditions associated to the fault in the More Details page are also cleared.