1503, SDI and V1004 Faults Page
Description
The Summary table displays 7 parameters for each fault. Parameters are continuously and automatically updated at a rate of about two times per second. The example below shows the parameters for a battery fault:
Description |
||||||
P0563 |
Active |
ECM |
|
|
|
Battery voltage too high |
To change the display of the summary table
From the drop down list, select the faults that you want to be displayed in the Summary table. You can choose between:
| All Faults |
| Active Faults |
| Active and Occured Faults |
To clear a particular ECM fault
| 1. | Select an ECM fault in the Summary table. |
| 2. | Click on the Clear Fault button. |
| 3. | Click on the message box Yes button. |
| 4. | Wait until B.U.D.S. clears the fault into the module. |
| 5. | Perform the ECM tracking procedure. |
To clear all occurred faults
| 1. | Click on the Clear Occurred Faults button. |
| 2. | Click on the message box Yes button. |
| 3. | Wait until B.U.D.S. clears all occurred faults into modules. |
| 4. | Perform the ECM tracking procedure. |
Notes
You can not clear an individual MPEM fault with the Clear Fault button.
Clearing a fault resets the Count, Cycle and Total time stamps to zero.
If you clear a fault that has a double star (**) preceding the fault code, then the conditions associated to the fault in the More Details page are also cleared.